Microtek i-MAXX 20KVA (3-1)

Categories: ,
  • Description

    Product Description

    Description

    • Online Double-Conversion.
    • DSP Technology guarantees High Reliability.
    • True Galvanic Isolation Transformer design.
    • Control designed to withstand all kinds of loads.
    • Independent Ventilation enhance durable operation under harsh environment.
    • Adjustable Battery numbers (29, 30, 31 & 32 Nos.)
    • Accept Dual-Mains Input.
    • Parallel Operation with upto 4 units (optional).
    • Reverse Phase sequence & no neutral operation.

    All Microtek Product Ranges are specially designed for the User’s Benefit.

    MODEL i-MAXX DSP TECHNOLOGY BASED ONLINE UPS SERIES
    Capacity 20KVA/16KW
    Phase Three Phase In / Single Phase Out
    DC VOLTAGE SYSTEM DEFAULT : 360VDC, ADJUSTABLE : 348-384VDC
    INPUT
    Nominal Voltage 3 x 380VAC/400VAC/415VAC (3Ph+N+G)
    Acceptable Voltage Range 165VAC ~ 280VAC (Ph-N) / 285VAC ~ 485VAC (Ph-Ph)
    Frequency Range 50Hz/60Hz ± 10 %
    EFFICIENCY
    Overall Efficiency (AC Mode) ≥ 88%
    Efficiency (Battery Mode) 90%
    BATTERY & CHARGER
    Battery Type/Battery Numbers Lead Acid/Tubular/SMF, Default: 30 Nos. (Adjustable 29,30,31 & 32)
    Charging Current Default 5A,Maximum=Capacity(KW)x(1-%Load)/Battery Voltage
    STATIC BYPASS
    Overload/Short-Circuit Capability 150% for 1 hour ; 180% for 30 sec ; >200% for 200 ms
    Connection Type/Input Voltage Range Hardwire 3-wire (1Ph+N+G) / 220VAC
    PHYSICAL
    Dimension LxWxH(mm)/Net Weight(Kgs.) 656x405x817 / 145Kgs.
    ENVIRONMENT
    Operating Temp./Humidity/Noise Level Temp.:0 ~ 55 ͦC / Humidity: 0 ~ 90% (non-condensing) / Less than 60dBA @ 1 Meter
    OUTPUT
    Nominal Voltage Default = 230Vac +/- 1%, 208VAC/220VAC/ 230VAC (Adjustable)
    Waveform Pure Sinewave
    Frequency Range (Synchonized mains Mode) 50Hz +/- 1%
    Frequency Range (Battery Mode) 50Hz +/- 0.1Hz
    Power Factor / Crest Factor 0.8 / 3:1
    Total Harmonic Distortion ≤ 2% (Linear Load) / ≤ 5% (Non-Linear Load)
    Transfer Time (AC to DC) 0 ms
    Transfer Time (Inverter to Bypass) 0 ms
    Overload Capability 110% for 10 minute, 150% for 60 Sec & > 160% for 200ms
    MANAGEMENT
    USB and Modbus RS-232/RS485 Supports Windows 2000/2003/XP/Vista/2008/7/8/10,Linux and MAC
    Dry Contacts / SNMP (Optional) 6 outputs and 2 inputs / Power management from SNMP manager and web browser (Optional)